Publications

Detailed Information

Stretchable Low-Impedance Conductor with Ag-Au-Pt Core-Shell-Shell Nanowires and in Situ Formed Pt Nanoparticles for Wearable and Implantable Device

DC Field Value Language
dc.contributor.authorSunwoo, Sung-Hyuk-
dc.contributor.authorHan, Sang Ihn-
dc.contributor.authorJung, Dongjun-
dc.contributor.authorKim, Minseong-
dc.contributor.authorNam, Seonghyeon-
dc.contributor.authorLee, Hyunjin-
dc.contributor.authorChoi, Suji-
dc.contributor.authorKang, Hyejeong-
dc.contributor.authorCho, Ye Seul-
dc.contributor.authorYeom, Da-Hae-
dc.contributor.authorCha, Myung-Jin-
dc.contributor.authorLee, Seunghwan-
dc.contributor.authorLee, Seung-Pyo-
dc.contributor.authorHyeon, Taeghwan-
dc.contributor.authorKim, Dae-Hyeong-
dc.date.accessioned2023-05-26T01:17:12Z-
dc.date.available2023-05-26T01:17:12Z-
dc.date.created2023-05-18-
dc.date.created2023-05-18-
dc.date.created2023-05-18-
dc.date.issued2023-04-
dc.identifier.citationACS Nano, Vol.17 No.8, pp.7550-7561-
dc.identifier.issn1936-0851-
dc.identifier.urihttps://hdl.handle.net/10371/192471-
dc.description.abstractMechanically soft metallic nanocomposites have gained much attention as a key material for intrinsically stretchable biointegrated devices. However, it has been challenging to develop a stretchable conductive nanocomposite with all the desired material characteristics including high conductivity, high stretchability, low cytotoxicity, and low impedance. Here, we present a material strategy for the stretchable conductive nanocomposite, particularly emphasizing low impedance, by combining silver-gold-platinum core- shell-shell nanowires and homogeneously dispersed in situ synthesized platinum nanoparticles (Pt NPs). The highly embossed structure of the outermost Pt shell, together with the intrinsic electrical property of Pt, contributes to minimizing the impedance. The gold-platinum double-layer sheath prevents leaching of cytotoxic Ag ions, thus improving biocompatibility. Homogeneously dispersed Pt NPs, synthesized in situ during fabrication of the nanocomposite, simultaneously enhance conductivity, reduce impedance, and improve stretchability by supporting the percolation network formation. This intrinsically stretchable nanocomposite conductor can be applied to wearable and implantable bioelectronics for recording biosignals and delivering electrical stimulations in vivo.-
dc.language영어-
dc.publisherAmerican Chemical Society-
dc.titleStretchable Low-Impedance Conductor with Ag-Au-Pt Core-Shell-Shell Nanowires and in Situ Formed Pt Nanoparticles for Wearable and Implantable Device-
dc.typeArticle-
dc.identifier.doi10.1021/acsnano.2c12659-
dc.citation.journaltitleACS Nano-
dc.identifier.wosid000970103900001-
dc.identifier.scopusid2-s2.0-85152643747-
dc.citation.endpage7561-
dc.citation.number8-
dc.citation.startpage7550-
dc.citation.volume17-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorLee, Seunghwan-
dc.contributor.affiliatedAuthorHyeon, Taeghwan-
dc.contributor.affiliatedAuthorKim, Dae-Hyeong-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordAuthorstretchable metallic nanocomposite-
dc.subject.keywordAuthorlow impedance-
dc.subject.keywordAuthorstretchable bioelectrode-
dc.subject.keywordAuthorcore-shell nanowire-
dc.subject.keywordAuthorin situ nanoparticle-
dc.subject.keywordAuthorimplantable bioelectronic-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Engineering
  • School of Chemical and Biological Engineering
Research Area Chemistry, Materials Science

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share